This product's A and B components are both packaged in plastic drums.
Component A: 20kg/drum Component B: 10kg/drum
INSPECTION ITEM | INSPECTION CONDITION | QUALIFICATION INDEX (GB50728-2011) |
|
---|---|---|---|
Colloidal Properties |
Tensile strength (MPa) | After 7 days of curing following the pouring, testing is conducted under conditions of (23±2)°C and (50±5)% RH. | ≥25 |
Tensile modulus of elasticity (MPa) | ≥1.5×10³ | ||
Elongation at Break (%) | ≥1.7 | ||
Flexural strength (MPa) | ≥30, and no fracture failure is allowed | ||
Compressive strength (MPa) | ≥50 | ||
Unrestrained Linear Shrinkage (%) | Test conducted after 7 days of curing following pouring, at a temperature of (23±2)°C. | ≤0.3 | |
Adhesive Capability | Steel-to-Steel Tensile Shear Strength Standard Value (MPa) | (23±2)℃, (50±5) %RH | ≤15 |
Steel-to-steel Bond Tensile Strength (MPa) | After 7 days of curing following pouring, testing is conducted at (23±2)°C and (50±5)% RH conditions. | ≥20 | |
The bonding tensile strength between steel and dry concrete (MPa) | ≥2.5, and cohesive failure within the concrete | ||
The bonding tensile strength between steel and wet concrete (MPa) | ≥1.8, and cohesive failure within the concrete |